Performance Data
Vistalux is excited and proud to announce the performance of our latest low-e coating development, VistaMax.
VistaMax has been designed specifically for European residential window manufacturers in mind. The same product can be used either annealed or heat strengthened.
Product | Treatment | VLT | U-Value | SHGC | VLRout | VLRin |
---|---|---|---|---|---|---|
CLR-VistaMax#2-4+16Ar+CLR-4 | Heat Strengthened | 81 | 1.25 | 66 | 14 | 14 |
CLR-4+16Ar+CLR-VistaMax#3-4 | Heat Strengthened | 80 | 1.26 | 64 | 12 | 13 |
SCL-VistaMax#2-4+16Ar+SCL-4 | Heat Strengthened | 82 | - | - | - | - |
SCL-4+16Ar+SCL-VistaMax#3-4 | Heat Strengthened | 82 | 1.26 | 69 | 12 | 13 |
SCL-VistaMax-4 | Heat Strengthened | 90 | - | 69 | 6 | 4 |
VistaMax represents an evolutionary improvement on our already successful PLE85A product.
Product | Treatment | Light | U-Value | SHGC | VLRout | VLRin |
---|---|---|---|---|---|---|
CLR-PLE85A#2-4+16Ar+CLR-4 | Heat Strengthened | 77 | 1.14 | 55 | 13 | 13 |
CLR-4+16Ar+CLR-PLE85A#3-4 | Heat Strengthened | 77 | 1.14 | 62 | 13 | 13 |
SCL-PLE85A-4+16Ar+SCL-4 | Heat Strengthened | 79 | 1.14 | 58 | 13 | 13 |
SCL-4+16Ar+SCL-PLE85A#3-4 | Heat Strengthened | 79 | 1.14 | 65 | 13 | 13 |
Note: A or AS = Air space, Ar = Argon, BS = Black Spacer, HS = Heat Strengthened, FT = Fully Toughened, HST = Heat Soak Tested.
CLR = Clear Glass, SCL = Low-Iron/Super-Clear, C.GR = Crystal Grey, E.GR = Euro Grey, E.BR = Euro Bronze, F.GR = French Green etc.
Unless noted otherwise the performance data provided is for the glass as noted in a thickness of 6mm.
Data is calculated using spectrophotometric measurements of representative factory production using NFRC 2001 protocols and LBNL Window 6.3 software. Control within ±5 % may not always be possible.
Visual aesthetics, appearance, amount of reflectivity and distortion of any glass selection will vary depending on the visual environment of the glass installation.
We recommend the purchase of a full-sized mock-up to be viewed on the job site by the designers and owners prior to final commitments.
Data subject to final confirmation by factory representitives.
CLR = Clear Glass, SCL = Low-Iron/Super-Clear, C.GR = Crystal Grey, E.GR = Euro Grey, E.BR = Euro Bronze, F.GR = French Green etc.
Unless noted otherwise the performance data provided is for the glass as noted in a thickness of 6mm.
Data is calculated using spectrophotometric measurements of representative factory production using NFRC 2001 protocols and LBNL Window 6.3 software. Control within ±5 % may not always be possible.
Visual aesthetics, appearance, amount of reflectivity and distortion of any glass selection will vary depending on the visual environment of the glass installation.
We recommend the purchase of a full-sized mock-up to be viewed on the job site by the designers and owners prior to final commitments.
Data subject to final confirmation by factory representitives.